Quantaurus-Tau Compact fluorescence lifetime spectrometer
Compact one-box fluorescence lifetime measurement system to measure fluorescence lifetime and photoluminescence spectrum with easy operation and high precision.
The Quantaurus-Tau is a compact system for quickly and easily measuring the fluorescence lifetime of photoluminescent materials from sub-nanoseconds to the millisecond range, with single-photon-counting sensitivity. Samples in different forms―thin films, solids, powders, and solutions―can be analyzed. Liquid samples can be cooled down to -196 deg.C (77K) with liquid nitrogen.
Operation is simple. Just load the sample into the sample chamber. Then enter a few conditions on the measurement software to measure the fluorescence lifetime and photoluminescence (PL) spectrum. It only takes a minute to get analysis results for a typical measurement. The measurement software includes a variety of measurement and analysis functions such as multicomponent analysis and multisample data comparison.
|
 |
Quantaurus-Tau Compact fluorescence lifetime spectrometer: C11367-11
Standard model. (Sample: Solution・Thin-film, Wavelength range: 300 nm to 800 nm)

|
 |
Quantaurus-Tau Compact fluorescence lifetime spectrometer: C11367-12
NIR model. (Sample: Solution・Thin-film, Wavelength range: 380 nm to 1030 nm)

|
 |
Quantaurus-Tau Compact fluorescence lifetime spectrometer: C11367-14
Standard model. (Sample: Solid (Thin-film・Powder), Wavelength range: 300 nm to 800 nm)

|
 |
Quantaurus-Tau Compact fluorescence lifetime spectrometer: C11367-15
NIR model. (Sample: Solid (Thin-film・Powder), Wavelength range: 380 nm to 1030 nm)

|
Quantaurus-QY Absolute PL quantum yields measurement system
Compact one-box absolute quantum yield measurement system for luminescence materials using photoluminescence method. Not only thin materials but also liquid solution and powder can be analyzed. It quickly measures the absolute PL quantum yield, excitation wavelength dependence and PL in a short time.
The Quantaurus-QY is a compact, easy-to-use instrument for measuring the quantum yield of photoluminescent materials. It performs absolute measurements and does not require known reference standards, as typically required when using the traditional relative method. Samples in different forms -thin films, solids, powders, and solutions- can be analyzed. Liquid samples can be cooled down to -196 deg.C (77K) with liquid nitrogen.
|
Quantaurus-QY Absolute PL quantum yields measurement system: C11347-11
Absolute quantum yield measurement system with detection range from 300 nm to 950 nm and detection resolution less than 2 nm (standard type).

|
 |
Quantaurus-QY Absolute PL quantum yields measurement system: C11347-12
Absolute quantum yield measurement system with detection range from 400 nm to 1100 nm and detection resolution less than 2.5 nm (NIR type).

|
 |